Biological Safety Cabinet Class II Type A2 Cabinet enclosure designed Class II Type A2 provides personnel, product and environment protection from hazardous particles such as bacteria, viruses and genetically manipulated materials such as nucleic acids that require Biosafety Level 1, 2 or 3 containments. Various applications in medical, biomedical, biotechnology, pharmaceutical, cell culture, tissue culture, virology and pathology applications using pathogens, genetic materials, carcinogens, allergens may generates hazardous airborne particles.

What is Biological Safety Cabinet Class II Type A2 ?

A biosafety cabinet —also called a biological safety cabinet or microbiological safety cabinet—is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with pathogens requiring a defined biosafety level.

Controller
- Integrated Digital microprocessor control system with graphic LCD display - Fan ON/OFF and 10-step adjustable air velocity - LED lamp ON/OFF - UV lamp ON/OFF - Adjustable UV sterilization timer - Elapsed time counter and alarm for HEPA filter replacement

Construction
- Durable epoxy powder coated metallic casing - Removable Stainless Steel 304 working plate

Performance
- Biological Safety Level Class II Type A2 design provides a higher level of personnel, product and cross contamination protection by keep filtrate airborne particles from the air stream - Inflow moves from the room air is drawn into the inlet grille at the work access opening and pass through a negative pressure plenum to blower creates HEPA filtered downward laminar air stream over the work area - Approximately 70% of the HEPA-filtered air is re-circulated through the cabinet into the work zone, while 30% passes through an exhaust HEPA filter and is discharged into the laboratory room air - Aluminum Frame Mini-pleated HEPA filters with nominal filtration efficiency of 99.993% ~ 99.995% for airborne particles larger than 0.3 um - Optional ULPA filter had higher filtration efficiency of 99.999% for airborne particles larger than 0.12 um

Convenience
- Ergonomic arm rest and 3 degree slanted front glass window - Removable working zone plate for easy cleaning and decontamination - Front service access panel for comfortable maintenance - The front door can also be closed fully to keep the cabinet interior clean during non-use period as well as to prevent exposure to UV radiation during sterilization - Epoxy powder coated SPCC exterior for durability - Silent and vibration free blower fan motor for comfortable working environment - LED lamp working light - 253 nm Germicidal UV lamp on working zone - Supplied with Base Stand with caster

Safety
- UV Lamp CUT-OFF In case of fluorescent lamp turned on - TOTAL USING TIME LOG - HEAP Filter replacement alarm - OVER CURRENT CUT-OFF : Fuse